You can click on the map below to determine the seismic design category SDC and response parameter S DS for that location. 2010 NYS BUILDING CODE FIGURE 161351 MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR NEW YORK STATE OF 02 SEC SPECTRAL RESPONSE ACCELERATION 5 OF CRITICAL DAMPING SITE CLASS B EarthquakeLoadsBC1613 build safe live safe 20 DeterminationofSeismicDesign CategoryBC161356.


Seismic Design Considerations For Elevators Installed In The U S Under Ibc Neii Org 703 589 9985

Use our IBC Seismic Design Categories map to easily obtain the seismic design category and spectral response acceleration parameter Section 1613 of the IBC 2015 for any location in the contiguous United States Puerto Rico and Alaska.

Seismic design category b nyc. Seismic Design Category B - Corresponds to buildings of Occupancy Groups III and III where expected ground shaking will be moderate. The design detailing fabrication and erection of structural steel seismic force-resisting systems shall be in accordance with the provisions of IBC 2205211 or 2205212. Seismic Design Categories Section 16163 Seismic Design Category Based on NYCBC Minimum Values I II III IV Structural Occupancy Category NYCBC Table 16045 Site Class S DS S D1 I II III Seismic Use Group NYCBC Table 16045 note a A Hard Rock 0195 0038 B B C B Rock 0243 0047 B B C C Very dense soil and soft rock 0292 0080 B B C.

TABLE 161356 1 SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD 02 SECOND RESPONSE ACCELERATIONS. Each building and structure shall be assigned to the more severe seismic design category in accordance with Table 161356 1 or 161356 2 irrespective of the fundamental period of vibration of the structure T. This Seismic Design Category incorporates the importance of the building its proximity to seismic fault lines and soil conditions at the site.

Seismic Design Category B or C IBC. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy suitability and applicability by. Seismic Design Category A Corresponds to buildings in areas where expected ground shaking will be minor.

While the determination path through codes standards might not be as clear as other system requirements seismic design is nonetheless a crucial component for the performance of a fire suppression system and an important consideration in the. While the information presented on this website is believed to be correct SEAOC OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. Seismic Design Category C D E or F Seismic Design Category SDC Importance Factor I p 10 I 15 Life Safety or Hazardous A EXEMPT Seismic Not Required EXEMPT Seismic Not Required B EXEMPT Seismic Not Required EXEMPT Seismic Not Required C EXEMPT Seismic Not Required REQUIRED D REQUIRED REQUIRED E REQUIRED REQUIRED.

Determination of the Seismic Design Category is complex and must be determined by a Registered Architect or Professional Engineer and should be. Select 1 Seismic Design Category. Category III structures that represent substantial hazard to human life.

In IBC structural classification and earthquake design category depends on parameter mapped spectral response acceleration at 1-S period S 1When S 1 is equal or greater than 075 the occupancy category III and III are assigned. The City College of New York. The project requirements which include the seismic design category can be found in Section 1 of the specification and on the first page of the structural drawings.

NYCDOT Seismic Design Guidelines for Bridges in Downstate Region prepared by Weidlinger Associates Inc. This file is 68mb and for better functionality it is recommended that you download the file to your PC then open it. The structure is also assigned to seismic design category E.

Also This file will not open in Bluebeam Revu. Category IV structures designated as essential facilities. The colors in the maps denote seismic design categories SDCs which reflect the likelihood of experiencing earthquake shaking of various intensities.

1 91 OVERVIEW New York State generally is not as seismically active as states that have areas located near tectonic plate boundaries. Building design and construction professionals use SDCs specified in building codes to determine the level of seismic resistance required for new buildings. How Seismic Design Categories Are Determined The seismic design category must be specified by a professional engineer or registered architect on the project drawings per ASCE 7.

Stratified soils with Good and poor Soils. Category II any structure not falling into Category I III or IV. Seismic Design NYSDOT Geotechnical Page 9-5 November 4 2015 Design Manual Rev.

The connections shall be capable of resisting the horizontal forces specified in Section 144 of ASCE 7 for walls of structures assigned to Seismic Design Category A and to Section 1211 of ASCE 7 for walls of structures assigned to all other seismic design categories. D21 561 Trapeze Supported Pipe in Seismic Design Categories A and B D21 562 Trapeze Supported Pipe in Seismic Design Category C D21 563 Trapeze Supported Pipe in Seismic Design Category D D21 564 Trapeze Supported Pipe in Seismic Design Categories E and F D21 57 Summary D21 60 Exemptions for HVAC Ductwork. Seismic Design Category The requirements for a suspended ceiling are determined by the buildings Seismic Design Category.

The probability of the State being struck by a major earthquake is small.


2020 Residential Code Of New York State Icc Digital Codes


2020 Building Code Of New York State Icc Digital Codes


Ruby7u4hw Rrym


1613 5 6 Determination Of Seismic Design Category


Wikipedia The Free Encyclopedia Skyscraper Architecture Eureka Tower Amazing Buildings


1613 5 4 Design Spectral Response Acceleration Parameters


2014 Nyc Building Code Ch 16 Structural Load Strength Of Materials


1613 5 6 Determination Of Seismic Design Category


Hino Rainbow Rh160 Motorhome Conversion First Choice Motorhomes Rv Kitchen Motorhome Conversions Kitchen


2306 6 Fiberboard Shear Walls


Chapter 16 Structural Design Nyc Building Code 2014 Upcodes


Chapter 16 Structural Design Building Code 2012 Of Hawaii Upcodes


Chapter 16 Structural Design Building Code 2018 Of Puerto Rico Upcodes


How To Determine If Sprinklers Require Seismic


Seismic Design Considerations For Elevators Installed In The U S Under Ibc Neii Org 703 589 9985


Https Www Dot Ny Gov Divisions Engineering Technical Services Geotechnical Engineering Bureau Geotech Eng Repository Gdm Ch 9 Seismic Design Pdf


2306 5 Particleboard Shear Walls


Http Www2 Cuny Edu Wp Content Uploads Sites 4 Page Assets About Administration Offices Fpcm Departments Cuny Consultant Design Guidelines 7 6 18 Pdf


2306 6 Fiberboard Shear Walls